Main Technical Data
◆ Frequency range: 1 Hz ~ 10 MHz (remote field testing: 1HZ ~ 10KHZ)
◆ Optional frequency : 1~8
◆ 3 mixing unit (automatic mixing)
◆ Fast digital / analog electronic balance
◆ Automatic Phase / Defect depth curves show
◆ Real-time alarm output, alarm output delay
◆ Mass storage can store a variety of testing procedures and test data
◆ Classification statistical test results (tables and histogram display), to facilitate the cumulative analysis of test results
◆ Can be equipped with access absolute, differential and self-comparison forms, including through type, interpolation type, flat type, point, rotary and other probe
◆ USB Interface, It is convenient and fast to connect the computer
Features
◇ Real-time quantifying flaw size
◇The role of multi-frequency, effectively inhibit the other parts of the interference signal
◇With a conventional multi-frequency, multi-channel eddy current testing system of ordinary advanced performance
◇Through the pipe wall can be detected inside and outside surface cracks,pits, corrosion, thinning, wall materials, internal defects by switch into multiple single-frequency eddy current instrument